EP3000 PLUS super power off grid inverter for solar system


Inside Structures

[ EP3000 PLUS 4-6KW ]

• Pure sine wave output
• Friendly user interface
• 3 Steps charging
• MFD (multi-function display)
• Overload and short-circuit protection
• Set charging voltage/charging current.
• Battery low voltage shutdown point can be set to 10/10.5/11V
• Power-save mode
• Set utility priority/ Battery priority
• Set utility input wide/narrow range
• Inverter voltage can be set to 120V:110V/115V/120V 220V:220V/230V/240V
• Inverter frequency can be set to 50/50/60Hz
• Set utility charging on/off switch
Pure sine wave output
Perfectly driving inductive load current


Smart Battery Chargers
Smart battery charger design for optimized battery performance.

Remote control
Control with a wired remote control panel
The remote control is particularly suitable when the power-source manager is installed behind a casing or in a place that prevents you from accessing the device. The remote control allows you to switch the power saving mode on/off easily. Please note that remote control panel is optional, not included in inverter package.
LCD display, easy to read how inverter operates on LCD screen

Line Mode
When utility is the unit the battery from the utility,LCD indicate charge current.

In utility mode the unit provide output power from the utility, the indication and displays are following figures:

Battery Mode
In battery mode the unit will provide output power from battery or PV, LCD indicate battery capacity.

1 ------- fan jam
2 ------- overload
3/6/7 ------- output short circuit
4 ------- over temperature
8/9 ------- battery over voltage.

Different working modes
You can choose different working mode based on your need.










EP3000 PLUS inverter system, it can work with battery as back up power for normal home power demands; meanwhile, you can also connect extra solar charge controllers and solar panels, as a complete solar system, which take use of sunshine freely and save lots electricity bill for you. This kindly of solar inverter systems are widely used in home, farm, school, shops etc

MODEL |
EP30-1KW PLUS |
EP30-1.5KW PLUS |
EP30-2KW PLUS |
EP30-3KW PLUS |
EP30-4KW PLUS |
EP30-5KW PLUS |
EP30-6KW PLUS |
||||||||||||||||||||||||||
Nominal Battery System Voltage
|
12VDC |
24VDC |
12VDC |
24VDC |
12VDC |
24VDC |
\ |
24VDC |
48VDC |
24VDC |
48VDC |
\ |
48VDC |
\ |
48VDC |
||||||||||||||||||
INVERTER OUTPUT |
Rated Power |
1.0KW |
1.5KW |
2KW |
3KW |
4KW |
5KW |
6KW |
|||||||||||||||||||||||||
Surge Rating(20ms) |
3.0KW |
4.5KW |
6.0KW |
9.0KW |
12KW |
15KVA |
18KW |
||||||||||||||||||||||||||
Capable Of Starting Electric Motor |
\ |
1HP |
1.5HP |
2P |
3P |
||||||||||||||||||||||||||||
Waveform |
Pure sine wave / same as input (bypass mode) |
||||||||||||||||||||||||||||||||
Nominal Output Voltage RMS |
220V / 230V / 240V (±10% RMS) |
||||||||||||||||||||||||||||||||
Output Frequency |
50Hz / 60Hz ±0.3Hz |
||||||||||||||||||||||||||||||||
Inverter Efficiency (Peak) |
>85% |
||||||||||||||||||||||||||||||||
Line Mode Efficiency |
>95% |
||||||||||||||||||||||||||||||||
Power Factor |
1.0 |
||||||||||||||||||||||||||||||||
Typical Transfer Time |
10ms(max) |
||||||||||||||||||||||||||||||||
AC INPUT |
Voltage |
230VAC |
|||||||||||||||||||||||||||||||
Selectable Voltage Range |
96~132VAC 155~280VAC(For personal computers) |
||||||||||||||||||||||||||||||||
Frequency Range |
50Hz / 60Hz(Auto sensing) 40~80Hz |
||||||||||||||||||||||||||||||||
BATTERY
|
Minimum Start Voltage |
10.0VDC / 10.5VDC for 12VDC mode(*2 for 24VDC, *4 for 48VDC) |
|||||||||||||||||||||||||||||||
Low Battery Alarm |
10.5VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC) |
||||||||||||||||||||||||||||||||
Low Battery Cut Off |
10.0VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC) |
||||||||||||||||||||||||||||||||
High Voltage Alarm |
16.0VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC) |
||||||||||||||||||||||||||||||||
High Battery Voltage Recover |
15.5VDC ±0.3V for 12VDC mode |
||||||||||||||||||||||||||||||||
Idie Consumption-Search Mode |
<25W when power saver on |
||||||||||||||||||||||||||||||||
CHARGER |
Output Voltage |
Depends on battery type
|
|||||||||||||||||||||||||||||||
Charge AC Input Breaker Rating |
10A |
30A |
30A |
30A |
40A |
||||||||||||||||||||||||||||
Overcharge Protection S.D. |
15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode) |
||||||||||||||||||||||||||||||||
Maximum Charge Current |
30A |
20A |
45A |
25A |
60A |
30A |
\ |
40A |
20A |
60A |
30A |
\ |
35A |
\ |
40A |
||||||||||||||||||
BYPASS & PROTECTION |
Input Voltage Waveform |
Sine wave (grid or generator) |
|||||||||||||||||||||||||||||||
Nominal Input Frequency |
50Hz or 60Hz |
||||||||||||||||||||||||||||||||
Overload Protection (SMPS Load) |
Circuit breaker |
||||||||||||||||||||||||||||||||
Output Short Circuit Protection |
Circuit breaker |
||||||||||||||||||||||||||||||||
Bypass Breaker Rating |
10A |
30A |
30A |
30A |
30A |
40A |
|||||||||||||||||||||||||||
Max Bypass Current |
30Amp |
||||||||||||||||||||||||||||||||
MECHANICAL SPECIFICATIONS |
Mounting |
Wall Mount |
|||||||||||||||||||||||||||||||
Dimensions (W*H*D) |
426*206*178mm |
601*206*178mm |
|||||||||||||||||||||||||||||||
Net Weight (Solar CHG)(kg) |
16.5 |
17 |
21.1 |
20 |
26 |
24.5 |
24.8 |
38.2 |
35.8 |
45.2 |
45 |
45.2 |
45 |
||||||||||||||||||||
Shipping Dimensions (W*H*D) |
5570*335*300mm |
750*335*300mm |
|||||||||||||||||||||||||||||||
Shipping Weight (Solar CHG)(kg) |
19.3 |
20 |
24.1 |
22.8 |
29.1 |
27.5 |
27.5 |
42.3 |
40 |
49.5 |
49.3 |
49.5 |
49.3 |
||||||||||||||||||||
OTHER |
Operation Temperature Range |
0℃ to 40℃ |
|||||||||||||||||||||||||||||||
Storage Temperature |
-15℃ to 60℃ |
||||||||||||||||||||||||||||||||
Audible Noise |
60dB MAX |
||||||||||||||||||||||||||||||||
Display |
LED+LCD |
||||||||||||||||||||||||||||||||
Standard Warranty |
1 year |