• Whatsapp : +8615552206756
  • E-mail: gavin@hangchisolar.com
  • EH9335-60KS series off grid solar power inverter

    Short Description:

    The EH9335 series UPS is three-in, three-out/three-in single-out high frequency online UPS. The product capacity covers all power range from 20kVA to 80kVA, which is convenient for users to configure flexibly. This series of UPS can solve almost all power problems, such as power outage, city power high voltage, city power low voltage, voltage drop, amplitude reduction, Power problems such as high voltage pulses, voltage fluctuations, surge voltages, harmonic distortion, clutter interference, and frequency fluctuations.


    Product Detail

    Product Tags

    Application field
    The EH9335 series is the best choice for data centers, network management centers, and enterprise server rooms in various industries or fields such as telecommunications, finance, transportation, government, manufacturing, and energy.

    Product performance

    Three in three out / three in single out UPS
    The series is a three-in and three-out UPS. The input current is three-phase balanced, which can equalize the load of the three-phase power grid; the output can be changed to single-phase output.
    Digital control
    All parts of the UPS are digitally controlled. The UPS has excellent performance indicators, high system stability, self-protection and fault diagnosis capabilities, and avoids the risk of analog device failure, making the control system
    more stable and reliable.
    The number of external batteries is optional (±16/18/20 sections are optional)
    The number of external batteries for this series of UPS can be selected according to the user’s needs: ±16/18/20 knots.
    Charging current can be set
    This series of UPS automatically assigns a reasonable charge current by setting the user-configured battery capacity.
    Constant voltage charging mode, constant current charging mode and floating charging mode can automatically and
    smoothly switch.
    Intelligent monitoring function
    This series of UPS can realize remote monitoring of UPS when an optional SNMP card is selected.
    Smart charging method
    This series of UPS uses an advanced two-stage three-stage charging method.?The first stage is high constant current charging, quickly recharge about 90% of the power; the second stage of constant voltage charging, can activate the battery characteristics and fully charge the battery; the third stage is floating charge mode.This can balance the goal of fast charging and extending battery life, saving users’ battery investment.
    LCD display
    This series of UPS uses LCD and LED dual display, which allows users to more intuitively understand the working status and operating parameters of the UPS such as input/output voltage and frequency load capacity, battery capacity and internal temperature, so that all operations can be seen at a glance
    EPO Function
    An emergency shutdown (EPO) button is embedded on the UPS unit panel,user can externally connect the EPO button.
    Press the EPO button in an emergency to shut down urgently; and have a remote emergency shutdown (REPO) function.

    TECH SPECS

    Model EH9335 PRO
    -20KS
    EH9335 PRO
    -30KS
    EH9335 PRO
    -40KS
    EH9335 PRO
    -60KS
    EH9335 PRO
    -80KS
    Power 20KVA/18KW 30KVA/27KW 40KVA/32KW 60KVA/54KW 80KVA/64KW
    Input Input  Three-phase four-line + ground
    Rated Power  380/400/415Vac
    Voltage Range  208~478Vac
     Frequency Range  45-55Hz at 50Hz/54-66Hz at 60Hz(Auto sensing)
     Power Factor ≥ 0.99
    Input Current Harmonic  ≤ 3%(100%Nonlinear load )
    Bypass  Range Bypass protection voltage upper limit:220V: + 25%(Optional+ 10%,+ 15%,+ 20%); 230V:+ 20%(Optional+ 10%,+15%);
    240V:+ 15% (Optional+10%)
    Bypass protection voltage lower limit:-45%(Optional -20%,-30%)
     Bypass frequency protection range:±10%
    Output Output  Three-phase four-line + ground or single phase+N
    Rated Voltage 380/400/415Vac or 220/230/240Vac
     Voltage accuracy ±1%
     Output Frequency Utility Mode Synchronous with input; when the mains frequency exceeds ±10% maximum
    (±1%, ±2%, ±4%,±5% can be set),
    the output frequency is 50*(±0.2)Hz
    Battery Mode  (50/60±0.2%)Hz
     Load peak Ratio  3:1
     Output Voltage Disortion ≤ 2% Linear Load
    ≤ 5% Nonlinear Load
    Battery Efficiency Normal Mode≥ 94.5%
    Battery Voltage Optional :±192V\±216V\±240V DC (±16/18/20  P CS)
    Charging Current 10A max
    Transfer time Utility mode to bypass mode: 0ms (tracking); utility mode to battery mode: 0ms
    Protection Overload Capability  Normal Mode Load ≤ 110%, 10mins, ≤ 125%, maintain 1mins,
    ≥ 150% shut down immediately.
    Over Temperature Protection  Normal mode: switch to bypass mode; Batter mode: Turn off the output immediately.
    Emergency shutdown
    (EPO)
     Turn off the output immediately
    Operating Environment  Communication Connection USB, RS485, dry contact, parallel (optional), SNMP card (optional), relay card (optional)
    Working Temperature 0o C ~ 40o C
     Storage Temperature -25o C ~ 55o C
     Relative Humidity  0℃~55℃ NO condensation
     Altitude < 1500m, when above 1500m, derate according to GB/T 3859.2
    Physical characteristics Size (D*W*H) 724*250*734mm 805*335*978mm
    Net Weight(kg)  45 46 48 80.5 82.5
     Executive standard  YD/T1095-2008

  • Previous:
  • Next:

  • Related Products